This section specifies the template ViewDefinitionContext.
The specification comprises a SysML Block that represents the template and an associated Parametric Diagram that defines the templates and PLCS PSMTemplate objects instantiated by the ViewDefinitionContext template.
The specification comprises the following sections:
The ViewDefinitionContext template describes how to represent a ViewDefinitionContext.
No templates have been explicitly defined as being related to the ViewDefinitionContext template.
Figure 1 shows the SysML Block that represents the template. The Block is an abstraction representing a pattern of templates and PLCS PSMTemplate objects.
The properties, i.e. the SysML Block Part, Reference and Value properties, of the template's SysML Block are described in the Template Properties section.
The output ports shown on the template's SysML Block are described in the template output ports section.
The SysML Parametric diagrams for the template Block are shown in template parametric diagram section.
The following SysML Part, Reference, and Value properties are defined for this template:
The following constraint, normally a uniqueness constraint, is applicable when instantiating the ExternalOwlObject:
rule.Ap239Ap233Psm.ExternalOwlClass.ur1ExternalOwlObject.individual
The following constraint, normally a uniqueness constraint, is applicable when instantiating the ExternalOwlObject:
rule.Ap239Ap233Psm.ExternalOwlClass.ur1ExternalOwlObject.individual
The following output ports are defined for this template:
There are no constraints defined for this template.
This section describes the template's Parametric Diagram. The diagram details the pattern of templates and PLCS PSMTemplate objects that are required to represent the template ViewDefinitionContext.
The public properties, i.e. those visible in the template's SysML block (See Figure 1) are shown on the left of a Parametric Diagram.
The output ports are shown on the right of a Parametric Diagram.
PLCS PSM objects are shaded khaki and Templates are shaded light green in a Parametric Diagram.
The following blocks are instantiated by this template and bound to private parts of the template as shown in the Parametric Diagram section:
The following constraint, normally a uniqueness constraint, is applicable when instantiating the ViewDefinitionContext:
rule.Ap239Ap233Psm.ExternalOwlClass.ur1The following constraint, normally a uniqueness constraint, is applicable when instantiating the ApplicationDomain:
rule.Ap239Ap233Psm.ExternalOwlClass.ur1The following constraint, normally a uniqueness constraint, is applicable when instantiating the LifeCycleStage:
rule.Ap239Ap233Psm.ExternalOwlClass.ur1Figure 3 shows the instances that have been instantiated in the template. These are used to set the default value of blocks.
The following instances have been created:
ExternalOwlObject.individual = http://docs.oasis-open.org/plcs/ns/plcslib/v1.0/data/contexts/OASIS/refdata/plcs-rdl#Product_life_cycle_support
ExternalOwlObject.individual = http://docs.oasis-open.org/plcs/ns/plcslib/v1.0/data/contexts/OASIS/refdata/plcs-rdl#Utilization_stage
There are no constraint blocks defined in this template.
No example data sets have been provided for this Template.