Template: OASIS:PhysicalBreakdown

This section specifies the template PhysicalBreakdown.

The specification comprises a SysML Block that represents the template and an associated Parametric Diagram that defines the templates and PLCS PSM objects instantiated by the PhysicalBreakdown template.

The specification comprises the following sections:

NOTE    An explanation of a template and its specification is provided in the Template overview

The PhysicalBreakdown template describes how to represent the decomposition of physical elements for a product.

The SysML Block Definition diagram in Figure 1 shows how a physical breakdown is represented in the PLCS PSM.

Figure 1 -  Physical Breakdown model.

No templates have been explicitly defined as being related to the PhysicalBreakdown template.

NOTE    The PhysicalBreakdown template may make reference to other templates as part of the Parametric Diagram. These are not listed here.

Figure 2 shows the SysML Block that represents the template. The Block is an abstraction representing a pattern of templates and PLCS PSM objects.

The properties, i.e. the SysML Block Part, Reference and Value properties, of the template's SysML Block are described in the Template Properties section.

The output ports shown on the template's SysML Block are described in the template output ports section.

Figure 2 -  Template block definition diagram for PhysicalBreakdown

The following Part, Reference, and Value properties are defined for this template:

References:
breakdownOf [1] (Block: Ap239Ap233Psm:BreakdownOfSelect)
The product that has been broken down.
Parts:
descriptions [0..*] (Template: OASIS:Descriptor)
The descriptions of the PhysicalBreakdown.
ids [1..*] (Template: OASIS:Identification)
The identifiers of the physical breakdown. There shall be at least one identifier for the physical breakdown. Hence there shall be at least one identifier classified to be a "Physical_breakdown_identification_code".
The reference data used in Template: OASIS:Identification is restricted as follows:
RDL constraint 1:
There must be one identifier that is the physical breakdown identifier.
The reference data for:
OASIS:Identification.role -> ExternalOwlClass.class
is restricted to the following class or a subclass:
names [0..*] (Template: OASIS:Name)
The names of the PhysicalBreakdown.
versionId [1] (Template: OASIS:Identification)
The identifier of the PhysicalBreakdownVersion.
NOTE    If no versionId is specified then a unique, unidentified PhysicalBreakdownVersion is created.
The reference data used in Template: OASIS:Identification is restricted as follows:
RDL constraint 1:
The identifier must be a version identifier.
The reference data for:
OASIS:Identification.role -> ExternalOwlClass.class
is restricted to the following class or a subclass:
classifications [0..*] (Template: OASIS:Classifier)
The classification of the PhysicalBreakdown
The reference data used in Template: OASIS:Classifier is restricted as follows:
RDL constraint 1:
The reference data for:
OASIS:Classifier.class -> ExternalOwlClass.class
is restricted to classes that are subclasses of the following class:

The following output ports are defined for this template:

physicalBreakdown (Block: Ap239Ap233Psm:PhysicalBreakdown)
Enables the Block: Ap239Ap233Psm:PhysicalBreakdown instantiated by this template to be referenced when the template is used.
physicalBreakdownVersion (Block: Ap239Ap233Psm:PhysicalBreakdownVersion)
Enables the Block: Ap239Ap233Psm:PhysicalBreakdownVersion instantiated by this template to be referenced when the template is used.
physicalBreakdownOf (Block: Ap239Ap233Psm:BreakdownOf)
Enables the Block: Ap239Ap233Psm:BreakdownOf instantiated by this template to be referenced when the template is used.

There are no constraints defined for this template.

This section describes the template's Parametric Diagram. The diagram details the pattern of templates and PLCS PSM objects that are required to represent the template PhysicalBreakdown.

The public properties, i.e. those visible in the template's SysML block (See Figure 2) are shown on the left of a Parametric Diagram.

NOTE    Restrictions on the reference data to be set on the public properties is defined in the Template Properties section.

The output ports are shown on the right of the Parametric Diagram.

PLCS PSM objects are shaded khaki and template shaded light green in a Parametric Diagram.

Figure 3 -  Parametric diagram for PhysicalBreakdown

The following blocks are instantiated by this template and bound to private parts of the template as shown in the Parametric Diagram section:

Private Part Property:physicalBreakdown [1] (Block: Ap239Ap233Psm:PhysicalBreakdown)
Private Part Property:physicalBreakdownVersion [1] (Block: Ap239Ap233Psm:PhysicalBreakdownVersion)
Private Part Property:physicalBreakdownOf [1] (Block: Ap239Ap233Psm:BreakdownOf)
Private Part Property:combNameAndDesc [1] (Constraint Block: OASIS:Name:CombineNamesAndDescriptors)

There are no instances that have been instantiated in this template.

There are no constraint blocks defined in this template.

No example data sets have been provided for this DEX.