Template: OASIS:MeasuredProperty

This section specifies the template MeasuredProperty.

The specification comprises a SysML Block that represents the template and an associated Parametric Diagram that defines the templates and PLCS PSM objects instantiated by the MeasuredProperty template.

The specification comprises the following sections:

NOTE    An explanation of a template and its specification is provided in the Template overview

The MeasuredProperty template describes how to represent a recorded value.

No templates have been explicitly defined as being related to the MeasuredProperty template.

NOTE    The MeasuredProperty template may make reference to other templates as part of the Parametric Diagram. These are not listed here.

Figure 1 shows the SysML Block that represents the template. The Block is an abstraction representing a pattern of templates and PLCS PSM objects.

The properties, i.e. the SysML Block Part, Reference and Value properties, of the template's SysML Block are described in the Template Properties section.

The output ports shown on the template's SysML Block are described in the template output ports section.

Figure 1 -  Template block definition diagram for MeasuredProperty

The following Part, Reference, and Value properties are defined for this template:

References:
name [1] (Block: Ap239Ap233Psm:ProxyItemSelect)
The name of the property that is recorded.
unit [1] (Block: Ap239Ap233Psm:ProxyItemSelect)
The unit of the property value that is recorded
measuringActivity [0..1] (Template: OASIS:ActualActivity)
The activity undertaken for measuring the value
measuredDuring [0..1] (Template: OASIS:ActualProductUsage)
The activity in which the product is operating when the property value is recorded
measuredByPersOrg [0..*] (Block: Ap239Ap233Psm:OrganizationOrPersonInOrganizationSelect)
The entity that records the property value
valueType [0..1] (Template: OASIS:Classifier)
The type of the recorded property value (i.e. Absolut, Increment)
Values:
dateMeasured [0..1] (Block: Ap239Ap233Psm:DateTimeString)
The date when the property value is recorded
value [1] (Real)
The recorded value

The following output ports are defined for this template:

measured_property (Block: Ap239Ap233Psm:NumericalValue)
Enables the Block: Ap239Ap233Psm:NumericalValue instantiated by this template to be referenced when the template is used.

There are no constraints defined for this template.

This section describes the template's Parametric Diagram. The diagram details the pattern of templates and PLCS PSM objects that are required to represent the template MeasuredProperty.

The public properties, i.e. those visible in the template's SysML block (See Figure 1) are shown on the left of a Parametric Diagram.

NOTE    Restrictions on the reference data to be set on the public properties is defined in the Template Properties section.

The output ports are shown on the right of the Parametric Diagram.

PLCS PSM objects are shaded khaki and template shaded light green in a Parametric Diagram.

Figure 2 -  Parametric diagram for MeasuredProperty

The following blocks are instantiated by this template and bound to private parts of the template as shown in the Parametric Diagram section:

Private Part Property:propValue [1] (Template: OASIS:PropertyValueNumeric)
Private Part Property:classifyProperty [1] (Template: OASIS:Classifier)
Private Reference Property:classMeasureValue [1] (Block: Ap239Ap233Psm:ExternalOwlClass)

The following constraint, normally a uniqueness constraint, is applicable when instantiating the ExternalOwlClass:

rule.Ap239Ap233Psm.ExternalOwlClass.ur1
Constraint: ur1
Specification: (OCL2.0)
ExternalOwlClass::allInstances()->isUnique(class)
Private Part Property:actDuringAsg [0..1] (Block: Ap239Ap233Psm:ActivityAssignment)
Private Part Property:classifyMDAsg [0..*] (Template: OASIS:Classifier)
Private Reference Property:classProductUsage [0..1] (Block: Ap239Ap233Psm:ExternalOwlClass)

The following constraint, normally a uniqueness constraint, is applicable when instantiating the ExternalOwlClass:

rule.Ap239Ap233Psm.ExternalOwlClass.ur1
Constraint: ur1
Specification: (OCL2.0)
ExternalOwlClass::allInstances()->isUnique(class)
Private Part Property:actMeasurementAsg [0..1] (Block: Ap239Ap233Psm:ActivityAssignment)
Private Part Property:classifyMAAsg [0..1] (Template: OASIS:Classifier)
Private Reference Property:classActivityOutput [0..1] (Block: Ap239Ap233Psm:ExternalOwlClass)

The following constraint, normally a uniqueness constraint, is applicable when instantiating the ExternalOwlClass:

rule.Ap239Ap233Psm.ExternalOwlClass.ur1
Constraint: ur1
Specification: (OCL2.0)
ExternalOwlClass::allInstances()->isUnique(class)
Private Part Property:poa [0..*] (Block: Ap239Ap233Psm:OrganizationOrPersonInOrganizationAssignment)
Private Part Property:classifyPOA [0..1] (Template: OASIS:Classifier)
Private Reference Property:classMeasurer [0..1] (Block: Ap239Ap233Psm:ExternalOwlClass)

The following constraint, normally a uniqueness constraint, is applicable when instantiating the ExternalOwlClass:

rule.Ap239Ap233Psm.ExternalOwlClass.ur1
Constraint: ur1
Specification: (OCL2.0)
ExternalOwlClass::allInstances()->isUnique(class)
Private Part Property:combTypes [1] (Constraint Block: OASIS:Classifier:CombineClassifiers)

Figure 3 shows the instances that have been instantiated in the template. These are used to set the default value of blocks.

Instance diagram
Figure 3 -  Model instance diagram for MeasuredProperty

The following instances have been created:

There are no constraint blocks defined in this template.

No example data sets have been provided for this DEX.