Template:— referencing_part (ref_part) Date: 2008/02/25 19:43:15
Revision: 1.12

Issue raised against: referencing_part

GENERAL issues


Closed issue Issue: RBN-1 by Rob Bodington (07-09-06) minor_technical issue
Resolution: Accept. Status: closed

The EXPRESS requires there to be a product categeory. ENTITY Part SUBTYPE OF (Product); WHERE WR1: SIZEOF(['part', 'raw material', 'tool']*types_of_product(SELF))=1; END_ENTITY;
Comment: (Leif Gyllstrom 07-11-20)
Added Product_category to the template.
Comment: (Rob Bodington 07-11-17)
It should be made clear in the template that Product_category is there to conform to the express. If a category of product is required, then reference data should be used.
Comment: (Johan Nielsen 2008-02-25)
Fixed.


Closed issue Issue: DNV-27 by David Skogan, DNV (2007-11-30) editorial issue
Resolution: Reject. Status: closed

Issue file: D:\users\rbn\projects\010937_DNV_dexlib\docs\review\checklists_12_07\all_template_issues.xls Template: referencing_part Check list clause: 9 Much of the text in the HTML is not present in template.xml, so I haven't checked it. But the spelling in template.xml is OK.
Comment: (Johan Nielsen 2008-02-25)
Spelling is OK.


Closed issue Issue: DNV-28 by David Skogan, DNV (2007-11-30) minor_technical issue
Resolution: Reject. Status: closed

Issue file: D:\users\rbn\projects\010937_DNV_dexlib\docs\review\checklists_12_07\all_template_issues.xls Template: referencing_part Check list clause: >rdl_ref is not used, even though Part_identification_code and Part_name are refered and linked to in HTML.
Comment: (Johan Nielsen 2008-02-25)
Parameter declaration uses the classifications and class-tag.


Closed issue Issue: DNV-29 by David Skogan, DNV (2007-11-30) editorial issue
Resolution: Reject. Status: closed

Issue file: D:\users\rbn\projects\010937_DNV_dexlib\docs\review\checklists_12_07\all_template_issues.xls Template: referencing_part Check list clause: 14 Why isn't Product_category and Product_category_assignment referred by >express_ref? >rdl_ref is not used, even though Part_identification_code and Part_name are refered and linked to in HTML.
Comment: (Johan Nielsen 2008-02-25)
Parameter declaration uses the classifications and class-tag.


Closed issue Issue: DNV-30 by David Skogan, DNV (2007-11-30) editorial issue
Resolution: Reject. Status: closed

Issue file: D:\users\rbn\projects\010937_DNV_dexlib\docs\review\checklists_12_07\all_template_issues.xls Template: referencing_part Check list clause: 16 >figure_ref is not used in XML.
Comment: (Johan Nielsen 2008-02-25)
Figures are not explicitly referenced in XML.


Closed issue Issue: DNV-31 by David Skogan, DNV (2007-11-30) minor_technical issue
Resolution: Reject. Status: closed

Issue file: D:\users\rbn\projects\010937_DNV_dexlib\docs\review\checklists_12_07\all_template_issues.xls Template: referencing_part Check list clause: 24 No purpose clause is given. It should be stated when a part should be referenced and when a part should be represented. It should also be described/exemplified how this template is going to be used by other templates.
Comment: (Johan Nielsen 2008-02-25)
The difference is made clear in the context of the capability representing_parts.


Closed issue Issue: DNV-32 by David Skogan, DNV (2007-11-30) editorial issue
Resolution: Reject. Status: closed

Issue file: D:\users\rbn\projects\010937_DNV_dexlib\docs\review\checklists_12_07\all_template_issues.xls Template: referencing_part Check list clause: 51 Entity types in underlying templates, such as asg_id, should not be used to describe the parameters. Remove references to External_class, External_class_library, etc.
Comment: (Johan Nielsen 2008-02-25)
Conforms to other templates. If still an issue should be raised for all templates.


Closed issue Issue: DNV-33 by David Skogan, DNV (2007-11-30) major_technical issue
Resolution: Reject. Status: closed

Issue file: D:\users\rbn\projects\010937_DNV_dexlib\docs\review\checklists_12_07\all_template_issues.xls Template: referencing_part Check list clause: 65 Cannot find the plcs_registerd.owl file. The one provided in dexlib is empty and refers to an url that does not exist.
Comment: (Johan Nielsen 2008-02-25)
OWL-file exists, ref. Rob Bodington.


Closed issue Issue: DNV-34 by David Skogan, DNV (2007-12-1) major_technical issue
Resolution: Accept. Status: closed

Issue file: D:\users\rbn\projects\010937_DNV_dexlib\docs\review\checklists_12_07\all_template_issues.xls Template: referencing_part Check list clause: 52b part_id_class_name and org_id_class_name should have default set to "Part_identification_code". part_id_ecl_id and org_id_ecl_id should have default set to "urn:plcs_rdl_std". An the above mentioned parameters should be optional.
Comment: (Johan Nielsen 2008-02-25)
Fixed.


Closed issue Issue: LOGSA-RI-1 by , LOGSA (2007-10-25) editorial issue
Resolution: Reject. Status: closed

Issue file: D:\users\rbn\projects\010937_DNV_dexlib\docs\review\LOGSA Template Reviews\template_issues.xls Template: referencing_part Check list clause: These not sequentially numbered: representing_part_tmpl, representing_part_char
Comment: (Johan Nielsen 2008-02-25)
Figures are numbered sequentially.


Closed issue Issue: LOGSA-RI-2 by , LOGSA (2007-10-25) editorial issue
Resolution: Reject. Status: closed

Issue file: D:\users\rbn\projects\010937_DNV_dexlib\docs\review\LOGSA Template Reviews\template_issues.xls Template: referencing_part Check list clause: Reviewers not identified.
Comment: (Johan Nielsen 2008-02-25)
Reviewers identified.


Closed issue Issue: LOGSA-RI-3 by , LOGSA (2007-10-25) editorial issue
Resolution: Reject. Status: closed

Issue file: D:\users\rbn\projects\010937_DNV_dexlib\docs\review\LOGSA Template Reviews\template_issues.xls Template: referencing_part Check list clause: Parentheses are used
Comment: (Johan Nielsen 2008-02-25)
OK with parentheses.


Closed issue Issue: LOGSA-RI-4 by , LOGSA (2007-10-25) editorial issue
Resolution: Reject. Status: closed

Issue file: D:\users\rbn\projects\010937_DNV_dexlib\docs\review\LOGSA Template Reviews\template_issues.xls Template: referencing_part Check list clause: Not found in plcs_registered.owl
Comment: (Johan Nielsen 2008-02-25)
Exists in different OWL-file, ref. Rob Bodington.


Closed issue Issue: RBN-2 by Rob Bodington (07-11-17) major_technical issue
Resolution: Accept. Status: closed

Should the template instantiate part_version as well and set up reference parameters to it?
Comment: (Rob Bodington 07-11-21)
It was agreed on telecon 2007-12-20 to include pat versions. It should be clearly documented that when the version is not known /NULL should be used
Comment: (Rob Bodington 07-11-21)
Added version parameters and corrected path. Diagram still needs to be updated
Comment: (Johan Nielsen 2008-02-25)
Fixed.


Closed issue Issue: RBN-3 by Rob Bodington (08-01-02) major_technical issue
Resolution: Accept. Status: closed

There should be reference parameters referencing the Identification_assignment so that effectivities and other characterizations can be applied to the Ids. recommend part_id_assgn
Comment: (Rob Bodington 08-01-03)
Added reference parameters: part_id_assgn part_version_id_assgn


Closed issue Issue: RBN-4 by Rob Bodington (08-01-03) minor_technical issue
Resolution: Accept. Status: closed

There should be a uniqueness constraint ensuring that there is only one version of a part with a given id.
Comment: (Rob Bodington 08-01-03)
Added constraint