Template:— assigning_dated_effectivity (ass_date_eff) Date: 2008/03/06 06:55:59
Revision: 1.19

Issue raised against: assigning_dated_effectivity

GENERAL issues


Closed issue Issue: RBN-1 by Rob Bodington (07-01-02) minor_technical issue
Resolution: Accept. Status: closed

A number of the input parameters should be defined types, not integers. The input parameters that are enumerations should have the enumeration specified.
Comment: (Rob Bodington 07-01-02)
Corrected.


Closed issue Issue: DNV-49 by Tore Hartvigsen, DNV (2007-11-14) editorial issue
Resolution: Reject. Status: closed

Issue file: D:\users\rbn\projects\010937_DNV_dexlib\docs\review\checklists_12_07\TORHAR_template_issues_temp.xls Template: assigning_dated_effectivity Check list clause: 6 master attribute not included
Comment: (Johan Nielsen 2008-02-22)
No source file available and not cost efficient to recreate, ref. Leif Gyllstrom.


Closed issue Issue: DNV-50 by Tore Hartvigsen, DNV (2007-11-14) editorial issue
Resolution: Reject. Status: closed

Issue file: D:\users\rbn\projects\010937_DNV_dexlib\docs\review\checklists_12_07\TORHAR_template_issues_temp.xls Template: assigning_dated_effectivity Check list clause: 7 no source files included in directory
Comment: (Johan Nielsen 2008-02-22)
No source file available and not cost efficient to recreate, ref. Leif Gyllstrom.


Closed issue Issue: DNV-51 by Tore Hartvigsen, DNV (2007-11-14) editorial issue
Resolution: Reject. Status: closed

Issue file: D:\users\rbn\projects\010937_DNV_dexlib\docs\review\checklists_12_07\TORHAR_template_issues_temp.xls Template: assigning_dated_effectivity Check list clause: 8 no source files included in directory
Comment: (Johan Nielsen 2008-02-22)
No source file available and not cost efficient to recreate, ref. Leif Gyllstrom.


Closed issue Issue: DNV-52 by Tore Hartvigsen, DNV (2007-11-14) editorial issue
Resolution: Reject. Status: closed

Issue file: D:\users\rbn\projects\010937_DNV_dexlib\docs\review\checklists_12_07\TORHAR_template_issues_temp.xls Template: assigning_dated_effectivity Check list clause: 22 One major cap issue still open
Comment: (Johan Nielsen 2008-02-22)
Major issue does not affect the template, ref. Rob Bodington.


Closed issue Issue: RBN-2 by Rob Bodington (08-03-06) minor_technical issue
Resolution: Accept. Status: closed

In assigning_dated_effectivity, almost all end_ parameters are optional, except end_sense and end_hour_offset. Why? Why do you need end_sense and end_hour_offset if you haven't specified any information for the end of the effectivity?
Comment: (Rob Bodington 08-03-06)